Level Switches - RF Admittance type

   -   Level Switches

Our RF level switch is widely applied in various products such as Building industry materials, cement, sand, lime, milk powder, flour, salt, food grains, powder, granular, chemical and mining etc. These comprise of a specially designed electronics and sensing probe using Driven Shield Coat Guard circuit and corresponding 3-Element Probe.

The electro-mechanical combination of the Coat Guard technique is there makes the system immune to the material build-up on the probe and material bridging between the probe and the hopper wall. The measured signal does not flow to the hopper wall through the probe in the backward direction but flows only through the material.


The salient features of this level measuring instrument are as follow:

  • Three Element Coat Guard Technology
  • Can be configured either for High or Low Level point switching
  • Reduces the Inventory cost
  • Ignores material build-up on the probe
  • Suitable for the highly dusty environment
  • High Reliability
  • Fast and Easy Installation Simple Calibration
  • Field selectable operation logic
  • Provides economical solutions
  • Various models not required 

The specifications of these point level switch are as follow:
 
Switching Unit:

  • Housing: Aluminum, weather proof, powder coated. Integral with The probe/ suitable for back panel mounting
  • Cable entry: 2 nos.
  • Ambient temperature: 0 ° C to +60° C
  • Power consumption: 1.9 VA
  • Mains Voltage: 230/110 V AC (+/-15%), 50 Hz OR 24 V DC
  • Output: 2 sets of potential free c/o contacts rated at 5 amps, 230 V AC for non-inductive loads
  • Switching delay: Continuously adjustable From 1 to 20 sec. probe Free or probe covered (Optional)
  • Safety operation: Field selected switch over for min. or max. (FSL/FSH) switching points
  • Switch status display: Green LED shows Normal, Red LED shows alarm, Yellow
  • LED shows power on condition 

Coat Guard Sensing Probe:

  • Mounting: Screwed 1 ½ BSP (standard) Or Flanged (optional)
  • Sense rod: Stainless steel
  • Shield: Stainless steel
  • Insulation: PTFE (standard) other on request and as per application.
  • Operating Temp in: 100 deg for the integral switching vessel unit.225°C for remote switching unit  

The Principle of Working:

The major shortcoming of the conventional method is that after the level has once increased and then decreased, there may be a coating left on the probe sensed by the instrument as though the level is still on the probe. In our switch, a coat guard amplifier is incorporated in the circuit having its output exactly at the same voltage and phase at all times as its input.

The output is connected through the shield of the low capacitance co-axial cable to the concentric tube on the sense probe, called shield element. There is no current flow through the cable as both the elements, sense and shield are exactly at the same potential and phase at all times.

This results in no change in calibration due to coating on the probe and the temperature effect of the cable. This makes it possible to increase or shorten the cable connecting the switching unit without changing the original calibration.

Level Switch - Boot type RF Admittance

Level Switch - PTFE coated RF Admittance

Level Switch - Remote mounted RF Admittance

Level Switch - RF Admittance type

Level Switch - RF Admittance type with Flange mounting & Stand Off

Level Switch - Rope type RF Admittance

RF Admittance Disc Probe Level Switch

RF Admittance Flange mounted

NK Instruments Pvt. Ltd.  Latest News & Events

NK Instruments Pvt. Ltd.

INVITATION for ChemTECH World EXPO 2017 at Mumbai

We INVITE you for ChemTECH World EXPO 2017 during 14th Feb to 17th Feb at Stall No. B10B Hall No.1. VENUE: Bombay Convention and Exhibition Center, Goregaon (East), Mumbai, INDIA
NK Instruments Pvt. Ltd.

AUTOMATION 2016 with ELECTRONET

We are at AUTOMATION 2016, at Bombay Exhibition Hall, Goregaon, Mumbai. This exhibition is started today and will be there up to 25th August 2016.
NK Instruments Pvt. Ltd.

INVITATION for AUTOMATION - 2016 at MUMBAI

NK Instruments Pvt. Ltd. Channel Partner of ELECTRONET, Invites you to Stall No. I - 24, 25, 26, 27 At Automation 2016 Between 22nd to 25th August 2016. Location: Bombay Convention and Exhibition Center, Goregaon(East), Mumbai, INDIA
NK Instruments Pvt. Ltd.

CRISIL Rating to NK Instruments Pvt. Ltd.

NK Instruments Pvt. Ltd. has got a NSIC-CRISIL rating as SE 3A

NK Instruments Pvt. Ltd.

International exhibition - PharmaTech / ChemTech 2013

We participated in a International exhibition - PharmaTech / ChemTech 2013 held at Goregaon, Mumbai from 15th to 18th Jan 2013. We could get a chance to meet our valued existing customers and also we could generate new contacts during the same.

NK Instruments Pvt. Ltd.

Chemtech 2011

We participated in Chemtech 2011 with our ORION brand products.

The show was from 23rd to 26th Feb 2011 at NSE Ehibition Ground, Goregaon, Mumbai

Read All News

Our Products  Our Top Product

Our Clientele  Our Clientele

Document

Download Catalog / Manual

Captcha image